HIGH VOLTAGE REED RELAYS

Introduction

Standard types - selection chart

Standard types - selection chart
GÜNTHER High Voltage Reed Relay technology is based upon our extensive experience in the design and manufacture of Reed Switches and Reed Relays.
GÜNTHER High Voltage Reed Relays have outstanding performance characteristics in insulation resistance and stand-off voltage. The high dielectric stand-off voltage between the open contacts as well as the high switching voltage are achieved by using high vacuum Reed Switches. A proven assembly and potting technique assures the following relay characteristics:
Stand-off voltage across open contacts from 3 KV up to 14 KV max.
Stand-off voltage between coil and contact from 10 KV up to 25 KV max.
Switching voltage from 1.5 KV up to 10 KV max.
GÜNTHER High Voltage Reed Relays are offered in a variety of contact configurations:
1 N.O., 2 N.O. or 4 N.O. contacts (normally open contacts)
1 N.C. (normally closed contact)
1 N.C. /1 N.O. (1 normally closed contact/1 normally open contact)
GÜNTHER High Voltage Reed Relays offer mounting flexibility enabling the customer to match different application requirements:
Coil and Reed Switch connecting pins in the base plate for PCB mounting
Coil connecting pins in the base plate for PCB mounting and Reed Switch connections with cable
Coil connecting pins in the base plate for PCB mounting and Reed Switch connecting pins on top of the relay
GÜNTHER High Voltage Reed Relays have additional features:
Immunity against harsh environmental conditions (e.g. high humidity) by using hermetically sealed switching contacts potted in a strong plastic case
High shock and vibration resistance
Low contact capacitance and high switching frequency in comparison with electro-mechanical open relay contacts
Washable and resistant to standard automatic cleaning methods
GÜNTHER High Voltage Reed Relays find application in many areas of the electrotechnical and electronic industry:
Electronic medical equipment
Cable tester arrays and cable test equipment
Copy machines
Laser optical systems and infra-red equipment
Test equipment
Type
1270 Number of contacts

Contact form:

Coil- and Reed Switch terminals:

1 contact

1 normally open

Soldering pins on bottom

4270 See type 1270

Contact form:

1 normally close
1280 Number of contacts

Contact form:

Coil terminals:

Reed Switch terminals:

1 contact

1 normally open

Soldering pins on bottom

Soldering pins on top

4280 See type 1280

Contact form:

1 normally closed
1290 Number of contacts

Contact form:

Coil terminals:

Reed Switch terminals:

1 contact

1 normally open

Soldering pins on bottom

High voltage cable on top

4290 See type 1290

Contact form:

1 normally closed
1272 Number of contacts

Contact form:

Coil terminals:

Reed Switch terminals:

2 contacts

2 normally open

Soldering pins on bottom

Switch 1 soldering pins on bottom  Switch 2 soldering pins on top

1274 Number of contacts

Contact form:

Coil- and Reed Switch terminals:

4 contacts

4 normally open

10 Soldering pins on bottom

1294 See type 1274

Reed Switch terminals:

High voltage cable at sides
5272 Number of contacts

Contact form:

Coil- and Reed Switch  terminals:

2 contacts

1 normally open and 1 normally closed

Soldering pins on bottom

5292 See type 5272  Reed Switch terminals: 

Coil terminals:

High voltage wires at each side   

Soldering pins on bottom

HIGH VOLTAGE REED RELAYS

CONTACT FORM 1 NORMALLY OPEN                                    1 NORMALLY OPEN
Type 3316 3316 3390 3391 3316 3390 3391 3392
  1270 1270 1270 1270 1280 1280 1280 1280
Data . .6 . .6 ..6 ..6 ..6 ..6 ..6 ..6
Contact Parameters
Switching voltage max Vpeak/VDC 1500 5000 7500 10000 1500 5000 7500 10000
Dielectric strength mm VDC 3000 7000 10000 14000 3000 7000 10000 14000
Switching capacity max W 30 50 50 50 30 50 50 50
Switching current max A 1 3 3 3 1 3 3 3
Carrying current max A 2 5 5 5 2 5 5 5
Contact resistance max mOhm 80 250 250 250 80 250 250 250
Coil Parameters
Nominal coil voltage VDC 5 12 24 5 12 24
Pull-in voltage max VDC 4 10 20 4 10 20
Drop outvoltage mm VDC 1 2 4 1 2 4
Operating voltage max VDC 8 18 36 8 18 36
Coil resistance +/-15% Ohm 35 200 720 35 200 720
Relay Parameters
Dielectric strength coil/contact VDC 20.000 20.000
Dielectric strength contact/contact VDC - -
Insulation resistance coil/contact Ohm 1 x 10E9 1 x 10E9
Storage temperature °C -35...+90 -35...+90
Operating temperature °C -20...+70 -20. .+70
Pull-in time incl. bounce max ms 3,5 3,5
Drop-out time ms 1,5 1,5
Dimensions page 20 20
Weight approx. g 55 55
1) Also available with high voltage cable (relay type 1290). Switches with contact code 90-92 are tungsten-plated and should he used onlv for switching power above aprox. 10 mW.

General Parameters

All characteristics for pull-in voltage, drop-out voltage and coil resistance at 20°C+/-3°C ambient temperature. For other temperatures see diagram temperature range.

Contact Resistance

Initial value at nominal voltage measured by the Kelvin test method at 20V/100mA.

Soldering

During soldering make sure no mechanical stress to be applied to terminals because the thermoplastic molding material might be damaged .

Order Example:

                         33    92   1270   05  6

Product group      Contact code    Standard type     Nominal coil voltage

05= 5V   12=12V   24 = 24V

Insulation Resistance

The insulation resistance is measured with a Tera Ohmmeter at 500V DC. The ambient climate is 20°C +/-3°C and 50 % relative humidity.

HIGH VOLTAGE REED RELAYS

CONTACT FORM - 2 NORMALLY OPEN 4 NORMALLY OPEN 1) 1 N.O.+ 1 N.C.1)
Type - 3316 3390 3391 3392 3316 3390 3391 3392 3316 3390 3391 3392
- - 1272 1272 1272 1272 1274 1274 1274 1274 5272 5272 5272 5272
Data - . .6 . .6 . .6 . .6 . .6 ..6 ..6 ..6 ..6 ..6 . .6 . .6
Contact Parameters
Switching voltage max VAC peak / VDC 1500 5000 7500 10000 1500 5000 7500 10000 1500 5000 7500 10000
Dielectric strength mm VDC 3000 7000 10000 14000 3000 7000 10000 14000 3000 7000 10000 14000
Switching capacity max W 30 50 50 50 30 50 50 50 30 50 50 50
Switching current max A 1 3 3 3 1 3 3 3 1 3 3 3
Carrying current max A 2 5 5 5 2 5 5 5 2 5 5 5
Contact resistance max mOhm 80 250 250 250 80 250 250 250 80 250 250 250
Coil Parameters
Nominal coil voltage VDC 5 12 24 5 12 24 5 12 24
Pull-in voltage max VDC 4 10 20 4 10 20 4 10 20
Drop-out voltage mm VDC 0,5 1,2 2,4 0,5 1 2 0,5 1 2
Operating voltage max VDC 7 16 29 7,5 14,5 27 7,5 14,5 27
Coil resistance +/-15% Ohm 15 85 275 12 42 175 27 135 345
Relay Parameters
Dielectric strength coil/contact VDC 10000 10000 10000
Dielectric strength contact/contact VDC 10000 8000 8000
Insulation resistance coil/contact Ohm 1 x 10E9 1 x 10E9 1 x 10E9
Storage temperature °C -35 +90 -35 +90 -35 + 90
Operating temperature °C -20 +70 -20 +70 -20 +70
Pull-in time incl. bounce max ms 3,5 3,5 3.5
Drop out time ms 1,5 1,5 1,5
Dimensions page 20 20 20
Weight approx. g 55 130 130
1) Also available with high voltage cable (relay type 1294 and 5292). Switches with contact code 90-92 are tungsten-plated and should be used only for switching power above approx. 10 mW.

Dielectric Strength Tested in a radiation (e.g. light x ray) free environment by applying a DC voltage across the open contacts between adjacent contacts and between coil and contact The test current is 100 µA. The unused contacts should not be connected during the test.

Switching Time Pull-in time including bounce time at nominal voltage and 20 Hz 1,5...3,5ms.

Release time (without diode) at nominal voltage and 20 Hz 0,4...1,5ms.

Contact Capacitance (Typical Values)

Capacitance N.0.

Across open contacts 0,8-1,2 pF

Between open contacts and coil 1,4-2,2pF

Between closed contacts and coil 2,3-3,5pF