TILT SWITCHES (Hg) ] I/O-MODULES ] SENSORS ] REEDSWITCHES ] SSR-WGA 4 - 8 ] [ METAL- TILT2 ] Sales Locations ]

TILT SWITCHES (Hg)

  in Metal Housings

cm100-0.jpg (1316 Byte)

Type

Fig

max Differential Angle

max. Switching Current in A max. Contact Resistance mOhm Mount
AC DC
30V 120V 240V 30V 120V 240V Features Clip
CM 100-0 1 10° 2,0 1 0 0,75 0,7 0,5 0,2 3 economical

choice of angle

3BH
CM 200-0 10° 4,0 2,0 1,5 1,7 1,0 0,4 3 3BH
CM 225-0 2 25°
CM 265-0 65°

CM 3000-0

3

24VDC 1,0 A

120 VAC 1,0 A

3 compact size 3BH

CM 3002-0

4 external long electrode
CM 3001-0 5 6-24 VAC/DC 1,0 A 3 small angle 3BH
* CM 1220-0 6 10° 0,5 0,2 0,2 0,5 0,2 0,1 3 two electrodes 1 A
CM 1300-0 7 10° 1,0 0,5 0,3 0,5 0,2 0,1 3 economical 1 A
CM 1323-0 8 10 0,5 0,25 0,2 0,5 0,2 0,1 1 two electrodes 1 A
CM 5000-0 9 10° 120 VAC 5,0 A , 120VDC 2.5A 3 high power 5DL
Miniature                                                                                              * Available on special order only. Consult factory.
CM 1360-0 10 30° 24VDC 0,25 A , 120 VAC 0,25 A 3 two single electrodes 1 A
CM 1600-0 11 24VDC 0,15 A , 12VDC 0,2A 10 single electrode, small housing 1 A
CM 1800-1 12 -- 120 VAC 0,1 A 5 for vibration sensing applications, two electrodes 1 A
CM 4400-0 13 -- 120 VAC 1,0 A 3 normally open, for vibration sensing applications 3BH
In general
  1. - Max differential angle is the angle between on and off state
  2.   Drawings show the installation orientation.
  3.   On and off switching angle depends on the mounting position
  4. - Switching material: Mercury,
  5.   Hermetically sealed
  6.   Operating temperature range -35 +105°C valid for all tilt switches on this page

 

TILT SWITCHES (Hg)

in Metal Housings

High Current

Type Fig max. Differential Angle max. Switching Current in A max.Contact Resistance inOhm Features  

Mount Clip

AC DC
30V 120V 240V 30V 120V 240V
CM 1000-0 1 10° 20 853 3 5DL
CM 1000-2 2 10° 20 10 5 8 5 3 3 2 mm quick connect terminals 5DL
CM 2000-0 3 10° 30 20 10 15 10 5 3 high current 9L
CM 2000-2 4 10° 20 20 10 10 10 5 3 2 mm quick connect terminals 9L
CM 1050-0 5 10° 20 10 5 8 5 3 3 change over, make before break 5DL
CM 2050-0 6 10° 30 20 10 10 10 3 3 change over; make before break 9L

 

 

 

 

 

 

 

 

In general
  1. - Max differential angle is the angle between on and off state
  2. - Drawings show the installation orientation
  3. - On and off switching angle depends on the mounting position
  4. - Switching material: mercury
  5. - Hermetically sealed
  6. - Operating temperature range -35 +105°C valid for all tilt switches on this page

 

Dimension