TIP-OVER SWITCHES (Hg)
Omnidirectional in Metal Housings
Type |
Fig | Operate Angle | max .Switching Current in A |
max. Contact Resistance In Ohm | Features |
Mount Clip | |||||
AC |
DC |
||||||||||
30V | 120V | 240V | 30V | 120V | 240V | ||||||
CM 1445-0 | 1 | * 45±10° | 2 | 1 | - | 0,7 | 0,5 | - | 3 | normally open, single electrode | 3 BH |
CM 1490-0 | 5 | * 45 ±15° | 2 | 1 | - | 0,7 | 0,5 | - | 3 | normally closed; single electrode | 3BH |
CM 1445-1 | 2 | * 45+10° | 2 | 1 | - | 0,7 | 0,5 | - | 3 | normally open, two electrodes | 3 BH |
CM 1490-1 | 6 | * 45 ±15° | 2 | 1 | - | 0,7 | 0,5 | - | 3 | normally closed, two electrodes | 3BH |
CM 1445-5 | 3 | * 45±10° | 2 | 1 | - | 0,7 | 0,5 | - | 3 | normally open, two electrodes with 90° bend | -- |
CM 1490-5 | 7 | * 45 ±15° | 2 | 1 | - | 0,7 | 0,5 | - | 3 | normally closed; two electrodes with 90° bend | -- |
CM 1445-7 | 4 | * 45±10° | 2 | 1 | - | 0,7 | 0.5 | - | 3 | normally open, two long electrodes with 90° bend | -- |
CM 1490-7 | 8 | * 45 ±15° | 2 | 1 | - | 0,7 | 0,5 | - | 3 | normally closed, two long electrodes with 90° bend | -- |
CM 1725-0 | 9 | * 25±10° | 2 | 1,5 | 0,8 | 1 | 0,6 | 0,2 | 5 | normally closed, single electrode | -- |
CM 1725-1 | 10 | * 25 ±10° | 2 | 1,5 | 0,8 | 1 | 0,6 | 0,2 | 5 | normally closed; two electrodes | -- |
CM 1790-0 | 11 | figure 11 | 2 | 1,5 | 0,8 | 1 | 0,6 | 0,2 | 0,025 | normally closed, two electrodes, x-y-angle different | -- |
CM 1745-1 | 12 | * 45+10° | 2 | 1,5 | 0,8 | 1 | 0,6 | 0,2 | 5 | normally closed, two electrodes with 90° bend | -- |
CM 1706-1 | 13 | * 6 ±2 '2 | 2 | 1,5 | 0,8 | 1 | 0,6 | 0,2 | 5 | normally closed, two electrodes | -- |
In general
|
TIP-OVER SWITCHES (Hg)
Omnidirectional in Metal Housings
High Power
Type | Fig. | Operate Angle | max. Switching Current in A | max.Contact Resistance In Ohm | Features |
Mount Clip | |||||
AC | DC | ||||||||||
30V | 120V | 240V | 30V | 120V | 240V | ||||||
CM 1535-5 | 2 | 35±10° | 30 | 12,5 | 7 | 15 | 8 | 5 | 3 | normally closed with single electrode UL approval. 120 VAC 1.500VA, 12,5A |
_ |
CM 1535-5 | 2 | 35±10° | 30 | 12,5 | 7 | 15 | 8 | 5 | 3 | normally closed with 2 quick connect terminals UL approval: 120 VAC 1.500VA, 12,5A | _ |
CM 1535-75 | 3 | 35±10° | 30 | 12,5 | 7 | 15 | 8 | 5 | 3 | n.c. with 2 q. c. terminals and nylon mounting bushing ULapproval 120 VAC 1 500 VA 12,5 A | _ |
CM 1535-70 | 4 | 35±10° | 30 | 12,5 | 7 | 15 | 8 | 5 | 3 | n.c. with epoxy sealed housing for horizontal mounting UL approval: 120 VAC, 1.500VA,12,5 A | - |
CM 1500-0 | 1 | 35±10° | 30 | 12,5 | 7 | 15 | 8 | 5 | 3 | normally closed with single electrode meets European appliance standards | - |
Special Switches |
|||||||||||
CM 4150-0 | 5 | * 4° typ. | 120 VAC/DC 1,0 A | 3 | 4 normally open solder pins closes one contact in every x-y-direction (Joystick) | - | |||||
CM 4150-1 | 5 | * 4° typ. | 120 VAC/DC 1,0 A | 3 | 4 normally open solder pins; 1 common pin closes one contact in every x-y-direction (Joystick) | _ | |||||
Miniature * Other operate angles available. Consult factory. |
|||||||||||
CM 1370-0 | 6 | * 60 ±10° | max. 120 VAC max 0,25 A | 3 | normally open, single electrode | _ | |||||
CM 1370-1 | 7 | * 60 ±10° | max. 120 V AC max. 0,25 A | 3 | normally open; two electrodes | _ | |||||
CM 1370-12 | 8 | * 60±10° | max. 120 VAC max 0,25A | 3 | normally open, two electrodes with 90° bend | _ | |||||
CM 1365-0 | 9 | figure 9 | max. 120 V AC max. 0,25 A | 3 | normally closed; two electr.;submin.;x-y-anglediff. | _ | |||||
* Other operate angles available .Consult factory. |